- Thương hiệu và xuất xứ:
+ UNIKA / XUẤT XỨ: TURKEY hoặc ITALY
- Đơn hàng tối thiểu: 100m/cuộn
- Tình Trạng: Còn hàng - Kho ĐÔNG NGUYÊN GIA - QUẬN 10
- Giá bán: Liên hệ
TECHNICAL DATA
Conductor : Tinned copper (optional bare copper) class 5 according to IEC 60228
Insulation : HF XLPE compound according to IEC 60092-360
Thickness according to IEC 60092-353 and to IEC 60092-376
Marking : For cross-sections 0,50 and 0,75 mm²
UNIKA (Italy) – SH-W 150/250 V 90°C cross-section – IEC 60092-376 – IEC 60332-1-2 – traceability code
For cross-sections 1 mm² and above
UNIKA (Italy) – SH-W 0,6/1 kV 90°C cross-section – IEC 60092-353 – IEC 60332-1-2 – traceability code
SHAPE \* MERGEFORMAT
Rated voltage : 150/250 V for cross-sections 0,50 and 0,75 mm²
0,6/1 kV for cross-sections 1 mm² and above
Rated conductor temperature : 90 °C
Fire behaviour
EC 60332-1-2 not fl ame propagation IEC 60754-1 halogen content
IEC 60754-2 pH and conducibility IEC 60684-2 fl uorine content
IEC 61034-1 and 61034-2 Smoke emission
SHAPE \* MERGEFORMAT
(*) Add to the code the letter corresponding to the color (Example: 1x1.5mm² orange N0017F).
(**) Add to the code the letter R for conductor in bare copper (Example: 1x1.5mm² orange, red copper conductor N0017FR).
Nhà nhập khẩu cáp điện Châu Âu UY TÍN - CHẤT LƯỢNG - ĐÓNG GÓI CHUYÊN NGHIỆP- GIAO HÀNG NHANH CHÓNG tại Việt Nam
CÔNG TY TNHH THƯƠNG MẠI VÀ XUẤT NHẬP KHẨU ĐÔNG NGUYÊN GIA
Tel : 028.62648106
Hotline : 0903624025 - 0909624025 ( Mr. Duy Đông)
Email: dongdng@dongnguyengia.com.vn
PHAN TRỌNG TUẤN (Mr) - 0908828979
Email: tuandng@dongnguyengia.com.vn
VŨ ĐÌNH HÀO KIỆT (Mr) - 0983778853
Email: kietdng@dongnguyengia.com.vn
HỒ THỊ CẦM (Mrs) - 0933467891
Email: camdng@dongnguyengia.com.vn
PHẠM ĐỨC MINH (Mr) - 0908899512
Email: minhdng@dongnguyengia.com.vn
NGUYỄN HỮU TOÀN THẮNG (Mr) - 0918508586
Email: thangdng@dongnguyengia.com.vn
TECHNICAL DATA
Conductor : Tinned copper (optional bare copper) class 5 according to IEC 60228
Insulation : HF XLPE compound according to IEC 60092-360
Thickness according to IEC 60092-353 and to IEC 60092-376
Marking : For cross-sections 0,50 and 0,75 mm²
UNIKA (Italy) – SH-W 150/250 V 90°C cross-section – IEC 60092-376 – IEC 60332-1-2 – traceability code
For cross-sections 1 mm² and above
UNIKA (Italy) – SH-W 0,6/1 kV 90°C cross-section – IEC 60092-353 – IEC 60332-1-2 – traceability code
SHAPE \* MERGEFORMAT
Rated voltage : 150/250 V for cross-sections 0,50 and 0,75 mm²
0,6/1 kV for cross-sections 1 mm² and above
Rated conductor temperature : 90 °C
Fire behaviour
EC 60332-1-2 not fl ame propagation IEC 60754-1 halogen content
IEC 60754-2 pH and conducibility IEC 60684-2 fl uorine content
IEC 61034-1 and 61034-2 Smoke emission
SHAPE \* MERGEFORMAT
(*) Add to the code the letter corresponding to the color (Example: 1x1.5mm² orange N0017F).
(**) Add to the code the letter R for conductor in bare copper (Example: 1x1.5mm² orange, red copper conductor N0017FR).